GOLD-PANEL COA™ · GOLD-PANEL COA™ ·8TESTS

The Gold-Panel COA standard

A basic COA shows purity. A Gold-Panel COA also confirms identity, measures content and screens for contaminants, and every test has to meet a published level before a lot carries the mark.

This page sets out the standard in full: what each test checks, how the lab runs it, what the report shows and the level it has to meet. Every current lot's report is published, and you can check any lot below.

LDAminos lots are registered in the Gold-Panel COA registry, where anyone can check each lot's badge.

The tests on every lot

Eight tests is the bar for every vial lot. Some labs run more; the mark requires these eight.

Identity: meets the Gold-Panel COA standard
Purity: meets the Gold-Panel COA standard
Net content: meets the Gold-Panel COA standard
Appearance: meets the Gold-Panel COA standard
Endotoxin: meets the Gold-Panel COA standard
Microbial: meets the Gold-Panel COA standard
Heavy metals: meets the Gold-Panel COA standard
Fentanyl screen: meets the Gold-Panel COA standard
Identity: meets the Gold-Panel COA standard

Identity

The molecule in the vial is the one on the label.

Why it matters
Every other number on a report only means something if the material is the right compound. Identity is checked first.
Method and instrument
Liquid chromatography coupled with mass spectrometry (LC-MS): the measured mass is compared with the expected molecular weight.
What the report shows
"Identity: Confirmed", with the compound the lab identified.
Gold-Panel pass level
Identity confirmed by mass spectrometry.
Purity: meets the Gold-Panel COA standard

Purity

How much of the peptide material is the target peptide.

Why it matters
Purity tells a lab how much of the peptide material is the target sequence and how much is related synthesis by-products.
Method and instrument
High-performance liquid chromatography with UV detection (HPLC-UV), run on two samples.
What the report shows
A percentage for each of the two samples and the reported purity, with the chromatogram.
Gold-Panel pass level
99.0% or higher.
Net content: meets the Gold-Panel COA standard

Net content

How much material is in the vial or capsule, measured.

Why it matters
A labelled amount is only useful if it is measured. Net content checks the label against the material.
Method and instrument
The lab measures the amount of each compound in two samples; for blends, each component is measured.
What the report shows
The measured amount in mg for each sample (and for each component of a blend).
Gold-Panel pass level
At least 90% of the labelled amount.
Appearance: meets the Gold-Panel COA standard

Appearance

The material looks as it should for its form.

Why it matters
A visual check catches handling problems, such as a collapsed cake or discoloured material, before any instrument runs.
Method and instrument
Visual inspection of the material as received by the lab.
What the report shows
The form and colour of the material, for example "White Lyophilized Powder".
Gold-Panel pass level
Conforms: lyophilized powder or capsules as labelled.
Endotoxin: meets the Gold-Panel COA standard

Endotoxin

Checks for bacterial endotoxin residue.

Why it matters
Endotoxins are residues of bacterial cell walls. They are invisible to HPLC, so they need their own assay.
Method and instrument
Limulus Amebocyte Lysate (LAL) assay, two replicates, assay sensitivity 0.05 EU/mL or lower.
What the report shows
Pass or fail for each of the two replicates, with the assay sensitivity.
Gold-Panel pass level
Both replicates pass.
Microbial: meets the Gold-Panel COA standard

Microbial

Checks for microbial contamination.

Why it matters
Microbial contamination is not visible on a purity trace. A DNA-based screen looks for it directly.
Method and instrument
Validated polymerase chain reaction (PCR) assay targeting common microbial contaminants.
What the report shows
"No Detectable Microbial DNA" or the contaminant found.
Gold-Panel pass level
No detectable microbial DNA.
Heavy metals: meets the Gold-Panel COA standard

Heavy metals

Arsenic, cadmium, lead and mercury.

Why it matters
Elemental impurities can come from reagents or equipment and do not show up on HPLC, so they are measured separately.
Method and instrument
Inductively coupled plasma mass spectrometry (ICP-MS) for arsenic, cadmium, lead and mercury.
What the report shows
Pass when all four are below the lab's reporting or specification limits.
Gold-Panel pass level
All four below the lab's reporting limits.
Fentanyl screen: meets the Gold-Panel COA standard

Fentanyl screen

Screens for fentanyl contamination.

Why it matters
Cross-contamination is a supply-chain risk for any powder. A targeted screen rules it out for each lot.
Method and instrument
A targeted screen for fentanyl on each lot.
What the report shows
"No Fentanyl Detected", or what was found.
Gold-Panel pass level
No fentanyl detected.

Why it’s demanding

  • Every test runs on every lot, not on a sample of lots.
  • The testing is done by an independent third-party lab, Freedom Diagnostics, which issues the report.
  • Purity has a floor: 99.0% by HPLC for every vial lot.
  • One failed or missing test and the lot does not carry the mark.
  • Lots that failed testing are not listed for sale.
  • Each current lot's report is published, with its lot number and report date.

Basic COA vs Gold-Panel COA

A purity-only COA reports HPLC purity. The Gold-Panel COA adds the tests below, each with a published pass level.

TestPurity-only COAGold-Panel COA
IdentityNot includedYes, with a pass level
PurityYesYes, with a pass level
Net contentNot includedYes, with a pass level
AppearanceNot includedYes, with a pass level
EndotoxinNot includedYes, with a pass level
MicrobialNot includedYes, with a pass level
Heavy metalsNot includedYes, with a pass level
Fentanyl screenNot includedYes, with a pass level

How a lot earns the mark

  1. 1

    Sample sent

    A sample of every new lot goes to an independent third-party lab.

  2. 2

    Full panel run

    The lab runs every test in the panel and issues the report.

  3. 3

    Checked line by line

    Every test has to meet its published level.

  4. 4

    Report published

    The report goes into the COA library with its lot number and date.

  5. 5

    Mark shown

    Only a lot that meets every level carries the Gold-Panel COA mark.

Gold-Panel COA is LDAminos's own standard. The testing is done by an independent third-party lab, Freedom Diagnostics; the pass levels are set and published by LDAminos.

Check a lot

Enter the lot number from the vial label or the report. 34 of 34 current lots meet the standard.

Every report is in the COA library. How the reports are read: quality standard. Buying in volume: wholesale & bulk.

Glossary

COA
Certificate of analysis: the lab's report of the tests run on one lot.
HPLC
High-performance liquid chromatography. It separates the components of a sample so the target peptide can be measured as a share of the peptide material.
LC-MS
Liquid chromatography with mass spectrometry. It measures molecular mass to confirm which compound is present.
ICP-MS
Inductively coupled plasma mass spectrometry. It measures trace elements such as arsenic, cadmium, lead and mercury.
PCR
Polymerase chain reaction. It detects microbial DNA in a sample.
EU
Endotoxin unit: the unit endotoxin assays report in.
Net content
The measured amount of material in a vial or capsule, compared with the labelled amount.
Lot
One production batch. Every lot gets its own report and lot number.

Frequently asked questions

What is a COA?

A certificate of analysis is the lab's report for one lot: which tests were run, how, and what each one found. Every current LDAminos lot has its own report, published in the COA library before you order.

What does the identity test confirm?

LC-MS measures the molecule's mass and matches it to the expected molecular weight, confirming the vial holds the compound named on its label. Identity is checked first; every other test is read against it.

What does purity of 99.0% or higher show?

HPLC separates the target peptide from related synthesis by-products and measures its share of the peptide material. Every vial lot has to reach 99.0%. Purity is a share of the peptide material, not of the powder's weight, which also holds water and salts.

Why measure net content?

Net content confirms the amount stated on the label is in the vial: the lab quantifies the peptide, and a lot has to measure at least 90% of the labelled amount. A purity figure alone cannot show how much material is present.

What do the contaminant screens look for?

Bacterial endotoxin (LAL), microbial DNA (PCR), the heavy metals arsenic, cadmium, lead and mercury (ICP-MS), and fentanyl. HPLC cannot see these, and most COAs report purity alone and skip them. A Gold-Panel lot has to pass all four screens.

Why eight tests?

Identity, purity, net content and appearance describe the material; the four screens look for contaminants. Together they answer the questions a lab asks of a research reagent, so eight is the bar for every vial lot.

Why is every lot tested?

Each production lot is its own batch, and measurements can differ from one lot to the next. A new lot gets its own report and its own LDAminos lot number; an older report never covers it.

Who does the testing?

An independent third-party lab, Freedom Diagnostics. Its name and accession number are on every report.

Who sets the pass levels?

LDAminos. Gold-Panel COA is LDAminos's own published standard: the lab runs the tests and reports what it finds, and the levels a lot has to meet are set out on this page.

For laboratory research use only. Not for human or veterinary use.